ZOZEN is a steam boiler manufacturer in China.

DZL (Vertical Single drum chain grate) Coal-Fired Steam Boiler

DZL (Vertical Single drum chain grate) Coal-Fired Steam Boiler

Capacity:0.5-10t/h

Pressure:0.7-2.5 MPA

Fuel:Bituminous Coal Lean Coal Anthracite

Temperature: 170-225℃

Applications: Heating, Chemical, Food, Tobacco, Textile, Printing and dyeing, Feed, Medicine, Building material, Wine, Rubber, Hospital

DZL (Vertical Single drum chain grate) Coal-Fired Steam Boiler introduction

  DZL series package boiler is a horizontal three-pass water and fire pipe chain grate boiler, which uses medium-sized bituminous coal. The boiler body is vertical single drum, and the threaded pyrotechnic tube is arranged in the drum to form a convection heating surface, and the drum and the water walls on both sides constitute a radiation heating surface of the furnace. The combustion equipment uses light chain grate, the whole package is finished in the factory. The electric control makes the governor stepless speed regulation, the limit parameter alarm and the interlock protection.

DZL (Vertical Single drum chain grate) Coal-Fired Steam Boiler parameters
 
 
 
Item
Model
DZL1-0.7-M
DZL1-1.0-M

 
DZL2-1.0-M
DZL2-1.25-M
DZL2-1.57-M
DZL2-2.45-M
DZL4-1.25-M
DZL4-1.57-M

DZL4-2.45-M
DZL6-1.25-M
DZL6-1.60-M
Rated thermal power(t/h/MW) 1/0.7 2/1.4 4/2.8 6/4.2
Rated working pressure(MPa) 0.7/1.0/ 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.6
Steam temperature/Rated output water temperature(℃) 170/184 184/194/204/225 914/204/225 194/205
 
Heating area(㎡)
Body 32.4 46.0 106.89 126.7
Economizer(㎡) 12.51 35.2 38.5 78.5
Effective area of grate (㎡) 2.05 3.70 5.30 8.32
 
Available
Coal                            AII、P、WII
Low heating value(KJ/kg) 21000
Fuel consumption(kg/h) 196 392 784 1176
Thermal efficiency(%) 79.00 79.00 79.00 79.00
Weight of biggest part for transportation(t)
 
13 22 30 23
Overall dimension of boiler transported LxWxH(m) 5.2x2.0x2.9 5.7x2.5x3.5 6.6x2.6x3.6 7.3x3.2x3.6
Overall dimension of boiler assembled LxWxh(m)
 
6.0x3.5x4.1 6.0x3.9x5.0 7.2x4.0x4.9 8.0x5.1x6.0

Notice: As the company's products continue to improve parameters of the above products will be continuously updated page listed for reference only.

 

DZL (Vertical Single drum chain grate) Coal-Fired Steam Boiler advantage
CNC manufacturing technology:
The key processing technologies such as steel plate blanking, circling, drum and tube plate drilling adopt advanced numerical control processing to reduce the assembly stress and prolong the service life of the boiler.
Steel pipe cutting, thread pipe pressing and convection pipe processing all adopt advanced numerical control technology.
The use of arched tube sheets and threaded fire tube was first adopted in China to increase heat transfer and completely solve the problem of cracking of the rear tube sheet.                                                   
The layout of chain grate is neat and beautiful, result in front and rear smoke box panel using CNC plasma cutting machine.
Advanced welding process
The vertical and circumferential seam welding of the boiler adopts advanced automatic submerged arc welding technology to ensure the welding quality. All vertical and circumferential welds are subjected to 100% ray detection.
The welding of smoke pipe and the tube plate adopts pre-expansion to eliminate the gap between the tube and tube plate, then be welded by automatic argon arc. Which effectively eliminate stress and prolong boiler life.
The flange of the socket is welded by robots.
The chain grate is manufactured by our factory, and it is tested for 72 hours before leaving the factory to ensure that the tightness is moderate and won’t go wrong.
Precision parts processing
Advanced manufacturing technology, using assembly line automatic spinning operation.
Enhance heat transfer and raise boiler thermal efficiency.
Threaded fire pipes are highly efficient heat transfer elements for many years of research by our company. After continuous optimization, the heat transfer coefficient is 1.8 times higher than that of conventional fire pipes when the selection of thread groove depth and pitch.
Unique structural design
Disturbed flue gas to ensure complete combustion of volatiles.
The air volume accounts for about 30% of the total, and the wind speed is about 50m³.
The independent secondary draft fan makes it easy to control and adjust the wind volume and pressure.
The high-temperature smoke generated by the combustion first enters the eight-character flue on both sides of the body from the tail (in this case, the water pipe type), and the flue gas flows outside the pipe.
The flue gas cooled by the eight-character flue then enters the threaded tube (in this case the fire tube type) arranged in the drum from the front smoke box.
The flue gas will be exhausted from the rear smoke box finally, this design fundamentally solves the problem of cracking of the tube sheet of a pure fire tube boiler.
Abundant auxiliary configuration
Sow feeder: sow feeder feed fuel equally to avoid flashback
Speed control gear: design reasonable rotating speed according to the combustion speed of biomass to make sure the fuel burning out.
Panels: cold-rolled embossed and concave-convex panels, strong and elegant.
Inspection door: reasonable manhole and hand hole layout, easy to maintenance. Furnaces are equipped with access doors for easy access and maintenance.
 

Get Price And Support

Fill in the following information, we will contact you in the shortest time ( * Denotes a required field ).

Pre:  Back to List

Next:  SZL(Vertical Dual drum chain grate) Coal-Fired Steam Boiler

Latest infomationMore>>
Hot products
ProjectsMore>>
Contact us

Email:   zhulin@zozen.com

Whatsapp:  +86-13506151292

Tele:  400-161-0099